GENERAL
After the town’s electric power is substation through high voltage to 24/12kV,it needs a plenty of area twice substation distributing to the user terminals. The safe and reliability of Substation device impact the stability of substation network directly.
Our company used computer Simulation technology, and combined product design and manufacturing experience for many years, developed new SF6 gas insulated mid-voltage switchgear device-ZBF unit switchgear, it is suitable to the need of network or user terminals. Also it is satisfactory for the need of the flexible using about compact switchgear by all kinds of twice substation.
ZBF unit switchgears is a fully enclosed system. All of the charged components and switchgear is enclosed in a stainless steel shell. The whole switchgear device dose not be impacted by the external environment conditions. So it ensures running reliability and personal safety and achieved the maintenance-free. By selecting extended bus , it can achieved any composition to full modular.
Extending bus fully enclosed and insulated ensure high reliability and safety. At the same time ZBF unit switchgears can provide switchgear automation solutions, formed intelligent switchgear concept to minimize the field installation and commissioning.
ZBF unit switchgears apply to three-phase AC 50Hz,and rated voltage 12kV distribution system be used as isolation and merger load current、overload current、commissioner of short circuit also breaking empty transformer、 a certain distance from overhead lines、 cable lines and capacitors, and other capacitive load, play the role of the distribution of power 、control and protection in power system. As a ring network and terminal equipment widely used in electricity supply cable network access points, breaking contact and multi-source, apply to the urban underground cables and radiation-ring network into the grid and connecting access control, as well as underground cables and overhead lines mixed network The Progressive access control and connection, and Central and radiation electricity supply network. Also It is used in :
Compact box-type substation 、Cable Branch Box 、Switching Station 、Wind Power Station small factories 、MTR and tunnels 、business center、shopping center、hotel、office building etc. |
SERVICE CONDITIONS
1.Normal service conditions
? Ambient temperature can’t past 40℃,and in 24h the detected average temperature can’t past 35℃.,the lowest ambient temperature is -15℃
? Altitude 2000m.
? Ambient air don’t be polluted by dust, smoke, corrosive and flammable gas, steam or salt spray.
? Humidity
Relative humidity: daily mean not greater than 95% ,monthly mean not greater than 90%
Water vapor pressure: daily mean not greater than 2.2kPa ,monthly mean not greater than 1.8Pa
? No regular shock
2.Special service conditions
? If the switchgear is used in the severe conditions, an agreement must be made between customer and manufacturer. |
MAIN TECHNICAL PARAMETERS
|
Items
|
Name
|
Units
|
Parameters
|
|
RK Loop
|
T Loop
|
|
1
|
Rated voltage
|
kV
|
12/17.5/24
|
|
2
|
Rated frequency
|
Hz
|
50
|
|
3
|
Current Rating
|
A
|
630
|
160
|
|
4
|
Rated current transfer
|
A
|
|
2300/1500/1150
|
|
5
|
Rated short-circuit breaking current
|
kA
|
|
31.5
|
|
6
|
Rated short-circuit the Commissioner of current
|
kA
|
50
|
80
|
|
7
|
Rated short-circuit the Commissioner of current (earth switches)
|
kA
|
50
|
|
|
8
|
Rated current short-term tolerance
|
Main circuit
|
kA
|
20
|
|
|
The earth switch
|
kA
|
20
|
20
|
|
Supporting the earth switch
|
kA
|
|
2
|
|
9
|
Rated short-term duration
|
Main circuit
|
S
|
3
|
|
|
The earth switch
|
S
|
3
|
3
|
|
Supporting the earth switch
|
S
|
|
3
|
|
10
|
Rated current peak tolerance
|
Main circuit
|
kA
|
50
|
|
|
The earth switch
|
kA
|
|
50
|
|
Supporting the earth switch
|
kA
|
|
5
|
|
11
|
Mechanical life
|
Load Switch
|
time
|
5000
|
|
Grounding Switch
|
time
|
2000
|
|
12
|
Rated breaking current closed-loop
|
A
|
630
|
|
|
13
|
Rated meritorious breaking load current (100)
|
A
|
630
|
|
|
14
|
Rated cable breaking current charge
|
A
|
10
|
|
|
15
|
Rated insulation level
|
Frequency Pressure
(1min)
|
- And to、relatively
|
kV
|
42/50/50
|
|
Fracture
|
kV
|
49/60/60
|
|
Lightning shock tolerance voltage (peak)
|
- And to、relatively
|
kV
|
75/125/125
|
|
Fracture
|
kV
|
85/145/145
|
|
16
|
Annually leakage rate
|
|
≤1%
|
|
17
|
SF6 Gas pressure(20℃Table pressure)
|
MPa
|
0.04±0.05
|
|
18
|
Pressure release device to release pressure
|
MPa
|
0.095~0.13
|
|
19
|
OEM Switchgear Kits & Shell and the level of security
|
|
IP3X
|
|
20
|
Fuse extinguishers / a box with electrical
|
|
IP67
|
|
NOTES FOR ORDERING
supply the following documents:
| a. |
All the types of the switchgear including the main circuit scheme number and the supplementary circuit scheme number. |
| b. |
The assembly sequence diagrams of the main circuit system. |
| c. |
The electric principle diagrams of the auxiliary circuit. |
| d. |
The inner cubicle components list. |
| e. |
The data of voltage,current,time in circuit. |
| f. |
The special requirements not under the normal service condition. |
|
Order Information
Location:
Minimum Order: 0
Price for Minimum Order: 0
(This price is only for minimum order. for large quantities, please contact)
Sample Available: no
Payment & Price Terms: Proforma invoice T/T or L/C
Delivery Lead Time:
Quality/Safety Certifications:
[Related Categories:
Power Distribution Equipment
]
[Related Keywords:
RMU
]
Contact Information
Mr. weng jimmy
(Marketing)
|
Company:
|
ZheBao Electrical (Hangzhou) Group Co., Ltd
|
|
Address:
|
yuzhangroad, hangzhou, zhejiang, China
|
|
|
|
Zip/Postal:
|
310024
|
|
Telephone:
|
86-571-88139986
|
|
Fax:
|
86-571-88139227
|
|
|
ICQ number:
|
Registration required to view contact details. |
|
MSN number:
|
Registration required to view contact details. |
|
Skype number:
|
Registration required to view contact details. |
|
Contact email:
|
Registration required to view contact details. |
|
|
|
|
Distribution and Transmission,
Outdoor High Voltage,
Distribution Box with,
Switchgear ,
Power Transformer ,
Three-Phase Distribution Board,
Enclosures ,
Distribution Box for,
ZW7-40.5 Type Outdoor,
screwable bushing ,
Dual-Line Terminal Power,
Terminal Block ,
VIB series vacuum,
Single Line Steel,
Standard Metal Enclosures,
Two-Circuit Terminal Poles,
Electrical Panel ,
steel towers ,
wind-Solar Hybrid Residence,
Electric Box
|
|